Cookie Consent by Free Privacy Policy website Toyota Installs Stationary Fuel Cell Generator Based on the Mirai FC System at its Honsha Plant in Japan
settembre 18, 2019 - Toyota

Toyota Installs Stationary Fuel Cell Generator Based on the Mirai FC System at its Honsha Plant in Japan

Comunicato Stampa disponibile solo in lingua originale. 

Verification tests begin, with the aim of verifying the generator's applicability in offices, plants, and other commercial scenarios 

Toyota City, Japan, September 18, 2019―Toyota Motor Corporation (Toyota) announces it has developed a stationary fuel cell generator (FC generator) that makes use of the fuel cell system (FC system) equipped in the Mirai Fuel Cell Electric Vehicle (FCEV). The FC generator has been installed within the Honsha Plant grounds in #toyota City, Aichi Prefecture, and verification tests have now commenced.

The FC generator uses two each of the FC system components equipped in the Mirai, including its FC stack, power control unit (PCU), and secondary battery. By using components from the #miraifcsystem, #toyota seeks to produce a high-performance generator at a reasonable price. Development on the generator was carried out jointly by #toyota and #toyota Energy Solutions, Inc.

For the verification tests, the electricity generated by the FC generator will be used inside the Honsha Plant; the generator will operate continuously for 24 hours per day, and generate a rated output of 100 kilowatts. The energy efficiency―the amount of electricity it generates per unit of hydrogen―the stability of the generated output, and the durability and ease of maintenance of the generator will be verified and evaluated.

Based on the results of the verification tests, #toyota intends to use FC generators as private power generators in an increasing number of plants. The generators will be fueled by hydrogen emitted both during the production process for FC system components, as well as during evaluation and testing processes; in this way, #toyota intends to develop and implement technologies that make effective use of hydrogen. In 2015, #toyota announced its #toyota Environmental Challenge 2050, one of which was the Plant Zero CO2 Emissions Challenge. In order to fulfil this challenge, #toyota will continue to steadily engage in reducing the amount of CO2 it emits during its production processes.

As part of its efforts to expand use of the FC system it developed for the FCEV, #toyota intends to consider the practical realization of the FC generator. This entails carrying out research and development and discussing the establishment of business models aimed at improving the generator's product appeal, by enhancing its energy efficiency and durability, making it more compact, and reducing costs.

Basic Specifications of FC Generator
  • Width × Length × Height2.3 × 4.5 × 2.5 m
  • Main FC systems taken from the MiraiFC stack, PCU, secondary battery, air compressor
  • Rated output100 kW
  • Power generation efficiency (transmission end)Goal of 50% or more
  • Rated voltage / number of phases / frequencyAC 210 V / three-phase three-wire / 50/60 Hz
  • Fuel cell typeSolid polymer electrolyte
  • Hydrogen purityPure hydrogen (99.97%)
  • Start-up time40 seconds (time to reach rated output)